per EN 1015-10
Determination of dry bulk density of hardened plastering mortar 450 ∓ 50 kg/M3
THERMAL CONDUCTIVITY
per EN 1745
Methods for determining thermal properties 0,052 W/mK T1 ≤ 0,10
WATER VAPOR PERMEABILITY
per EN 1015-19
Determination of water vapour permeability of hardened rendering and plastering mortars ≤ 15μ
COMPRESSIVE STRENGTH
per EN 1015-11
Determination of flexural and compressive strength 2,85 – 3,50 (N/mm2-MPa) CII
ADHESIVE STRTENGTH
per EN 1015-12
Determination of adhesive strength of hardened rendering and plastering mortars on substrates ≥ 0,30 ( N/ mm2 – MPa )
WATER ABSORPTION
per EN 1015-18
Determination of water absorption coefficient due to capillarity action of hardened plastering mortar ≤ 0,2 (Kg/m2) – W2
How To Install Ekoplast 50
Application
Apply over solid backing of concrete, cement block, brick, drywall, plasterboard, OSB,
steel structures and many other substrates.
Temperature
Mix and apply EkoPlast-50 when the ambient and surface temperature is at least 40° F and rising. Ambient
and surface temperature must not exceed 120°F during and 24 hours after application
Surface Preparation
Surfaces must be structurally sound, clean, dry and free of dust, dirt or other contaminates impairing bond. Prepare the surface to be smooth and free of cracks, holes and voids.
Mixing
For every bag of EkoPlast-50 use 3 gallons of water (Add water if needed to achieve desired consistency). Place quarter of the water in the mixing container and mix while slowly adding a bag of EkoPlast-50 and the rest of the water. Mix for 6 to 8 minutes until it reaches a homogeneous consistency. Continued mixing can be applied as long as each batch is mixed for min 6 minutes. Prepare only enough mixture that can be applied within 2 hours with pumpsprey or trowel.
Installation
Apply EkoPlast-50 by trowel or pumpspray in such a way to press the material into the substrate for bond
strength. Apply a minimum thickness of 3/8" over existing surface. On new installations apply a minimum of 3/4" and up to 1"
thickness can be applied in a single coat. Use screeds where necessary to control the thickness for an even flat finish.
There are various finish trowel techniques to create
a variety of final finishes. Wait 72 hours (should be adjusted according to weather conditions) before painting.